1.SYSTEM REQUIREMEMENTS #

In order to use System Pro the computer must run with any of the following operating systems:

  • Windows XP Professional / Home Edition
  • Windows Vista
  • Windows 7
  • Windows 8
  • Windows 10

 

The following minimum requirements are necessary:

Operating System

                      Minimum Requirements

Windows XP Professional / Home Edition
  • Intel Pentium Processor (or compatible) at 300 MHz or greater
  • 256 MB of RAM
  • 200 MB of free space on hard drive
  •  CD-ROM Unit or DVD-ROM
Windows Vista, Windows 7 e Windows 8
  • Intel Processor (or compatible) 800 MHz
  • 512 MB of RAM
  • 200 MB of free space on hard drive
  • CD-ROM Unit or DVD-ROM
Windows 10
  • Processore Intel (or compatible) 800 MHz
  • 512 MB of RAM
  • 200 MB of free space on hard drive
  • Unità CD-ROM Unit o DVD-ROM

 

2.INSTALLATION #

To install System Pro:

  • Click on mysetup.exe icon
  • Follow the wizard installation procedure as shown in the following images.
  • At the end of the installation start the System Pro software from the Desktop icon.
  • Select the desired language from the start screen.

3.MAIN SCREEN #

The System Pro software allows the user to customize the management and visualization screen of TiEmme Elettronica control systems. The quick menu buttons on the bar Menu allows the user to quickly access the main features of the software.

3.1.QUICK SELECTION BUTTONS #

C:Usersg.ranieriDesktopImmagini2016-04-26 17_55_22-TiEmme SystemPro (TIEMME SERVER PRINCIPALE) v. 0.1.1.57.png Products Database
  • Access to products in the Database
C:Usersg.ranieriDesktopImmagini2016-04-26 17_57_27-TiEmme SystemPro (TIEMME SERVER PRINCIPALE) v. 0.1.1.57.png Product Connection
  • Opens products based on the connection established with the control-board
C:Usersg.ranieriDesktopImmagini2016-04-26 18_01_07-TiEmme SystemPro (TIEMME SERVER PRINCIPALE) v. 0.1.1.57.png Settings
  • Opens the Settings Menu window
TPX Generator
  • Starts the TPX Generator function (this is visible only if it has been previously installed in the PC)
Firmware Download
  • Opens the window to start the Wizard that allows the firmware download of the control-board/panel
Address Book
  • Access to the Address Book menu
User Change
  • Access to the user selection window

3.1.1.PRODUCTS DATABASE #

Click the Products Database to access the Database Product list.

 

With this window the user may select the desired product that is identified with a System Evo code and its description. When selecting a product its program list is displayed; In the right window the user can view the selectable languages, the author, the creation date and any modifications with the related description. Furthermore it is possible to remove existing products in the database by using the Remove button, or import new products with the Import button. To access the desired product select it and press the OK button. Next, access the language window that can be used for the selected product. Select the desired language and press the OK button.

3.1.1.1.EVO Cloud #

La funzione EVO Cloud è disponibile effettuando l’accesso nella sezione 4HEAT Connection Credentials con diritti SuperVisor

Fig 6

La schermata è così composta:

  • Codice EVO: codice univoco che rappresenta il set parametri della scheda di controllo
  • Descrizione: descrizione del prodotto corrispondente al codice EVO
  • Ver: Versione del database del prodotto
  • Delete: Pulsante di cancellazione del prodotto, disponibile solo per un prodotto già scaricato
  • State: stato del prodotto,
    •  indica che è stato scaricato il pacchetto relativo al prodotto e visualizzabile nella sezione Area Documentale locale
    • indica che il pacchetto è disponibile per essere scaricato ma non presente in locale.
  • Validate: flaggando il campo si identifica la versione di quel prodotto che è stata validata per l’utilizzo

È possibile scaricare un prodotto in tre modi:

  • Effettuando doppio click su una versione del prodotto non scaricata
  • Cliccare sulla nuvola blu per scaricare la versione del prodotto interessato
  • Selezionare la riga della versione del prodotto e cliccare su Download

Al termine della procedura di Download, effettuando doppio click sul prodotto, si può aprire l’area documentale Fig. 8.

All’interno dell’Area documentale si trova il contenuto della versione del prodotto appena scaricato, visibile in alto a sinistra, effettuando doppio click sopra il file Default_IT.tim o Default_EN.tim a seconda della lingua selezionata, verrà importato il set parametri relativo al file selezionato.

3.1.2.PRODUCT CONNECTION #

Click on the icon Product Connection to connect to the Control-Board. It is possible to select one of the following connection modalities:

1. Serial Communication: For this type of connection the TiEmme Control-Board must be connected to the PC via USB Programmer or KeyPRO device. The window displays the COM ports to which the TiEmme Control-Boards can be connected. Click the Device Control button to check all products connected to the respective COM ports of the PC. Select the desired COM port and select it with the Open Device button.

2. TCP/IP Connection: For this type of connection the Control-Board must be connected with the Easy2Check (E2C) device.

  • If the E2C device is configured in Server modality it is necessary to connect with the System Pro by inserting the IP address assigned to the E2C in the Host field during the configuration phase. In addition it is necessary to assign the value of the relative port: default value of 9000. Next click on button Connect.
  • If instead the E2C device has been configured as Client it is necessary to connect to the System Pro with the Server field by inserting the relative listening Port and ID of the E2C which can be found in its own configuration page. Next click on Listen.

In both modes it is possible to access directly to the Address Book where the user-preset contacts can be found. (see. Par.4.1.6)

3. Modem GSM Connection: In this section the user can perform the preliminary steps required to connect to the Control-Board via GSM modem. Select the COM port associated with the modem and enter the relevant phone number. Then click the Call button. The user may access the preset-contact list via the Address Book button (see. Par. 4.1.6). With System Pro a modem can be used to connect remotely to a Control-Board. The modem will need a SIM card capable of supporting a GSM data connection. The user must connect the modem to the control-board and provide it with a SIM card that can support a GSM data connection. The PIN request must be disabled. Even though the software and the controller have an inactive connection time-out for 5 minutes (after which the modems are disconnected), remember to always disarm the modem whenever it is unused.

TiEmme elettronica cannot be held liable if the modem connection remains active for an indefinite period of time.

When finished with the modem-connection click on the Hang-up button to end the communication with the remote Control-Board. Should System Pro signal any errors during the disconnecting phase it is recommended to turn off the modem. Remember that if the active connection remains unused for more than 5 minutes System Pro and / or the Control Board will end the connection.

3.1.3.SETTING #

The Settings menu allows the user to access the features that are described below.

3.1.3.1.LANGUAGES #

With System Pro the user may select a language from the list below to manage the software:

  • Italian
  • English
  • Spanish
  • French
  • German
  • Russian

 

If the user has Administrator privileges he/she may access the Translation option. To enable this option the user must select the Default English language. In this tab the user can insert and edit the translations of the individual descriptions of the software interface.

 

 

The Translator Editor mode allows the user to compare between the default English Language and the chosen language of the user. It can also be used to modify the single translations of the text strings of the software by using the following tools:

  • Search: The user can search for specific text strings or single words in the English reference column through the field Search (en) or in the desired language with search field Search on Language. The user may also search for untranslated text strings by ticking the check box Only not Translated.
  • Upload translation file: The user can upload the translation library file by clicking the Load Language data button. In this case the user will import a text file where translated strings must be placed in column format.
  • Export Language file in English: The user may export the English text string file. The file can be opened with any text software. The English text strings are placed in column format, can be translated manually or can be imported in an automatic translator.

3.1.3.2.SAFETY #

In the Safety menu it is possible to change both the Administrator and Standard User passwords. This function is only available in Administrator mode.

3.1.3.3.DATABASE AND FOLDERS #

The tab Database and Folders, can only be accessed with Administrator privileges and allows the user to:

  • Select a Local Database or a Company Server. This option allows the user to centralize the database on the company server thereby allowing multiple users to access the same database.
  • Choose to enable the database log and store it in a specific folder.
  • Select the default time of the device Log (see. Par. 5.5)

3.1.3.4.APPEARANCE #

The Appearance tab allows the user to modify the font used for the System Pro software interface strings. With the Select Font button it is possible to select one of the following:

3.1.3.5.4HEAT CONNECTION CREDENTIALS #

INTEGRARE

3.1.4.TpX GENERATOR #

To access this function, click the TPX Generator button on the Quick Selection Buttons menu, which will only appear if TPX Generator has been correctly installed. When the software opens the following screen appears.

For more information about the TPX Generator, refer to the manual “DMANH01000001 – User Manual Key Pro EN.pdf” which is automatically saved in the file C:Program Files (x86)TiEmme elettronicaTPxGenerator.

3.1.5.FIRMWARE DOWNLOAD #

The following tab allows the user to manage the firmware reprogramming of the control-board and the USB Programmer device.

Select the communication Port (COM port) to be used, click on the green arrow to automatically update the COM port list.

Firmware programming can be performed in three different modalities:

  1. Firmware reprogramming of TiEmme devices.
  2. Downloading the Firmware in the USB Programmer
  3. Device firmware update USB Programmer

3.1.6.ADDRESS BOOK #

System Pro includes an address book to memorize contact details of clients who choose to use remote connectivity. In the Quick Selection Buttons Menu click on the Icon Address Book

To add a new contact click on the New button. An empty entry is added to the contact list. All voices indicated must be filled in detail. After a new contact has been created it is possible to add one or more devices to connect to by clicking on button Add Device. The user may also remove any unwanted devices by clicking on the button Remove Device. To modify any Client Data click on Save after having made the necessary modifications. To remove a contact click on Remove. The Address Book also comes with a search utility to find names, references etc. By selecting items in the Filter frame the user can filter the search in the desired field.

3.1.7.CHANGE USER #

From the Quick Selection Buttons menu click on the Change User button to open the following tab that allows the user to change access credentials in System Administrator or Standard User.

4.PRODUCT MANAGEMENT #

To manage a product the user must first select it (see Par.4.1.1). An expandable and customizable tree menu is located to the left of the work screen. For explanatory simplicity the inside this tree-type menu the user can identify the item’s level by their colors in the following manner:

  • Functions or Main Folder: highlighted in green
  • Sub Folders: highlighted in blue
  • Tab: highlighted in pink

The menu includes the management of the EVO product identifiable by device ID (evo code, in this case SYEVO0000482) and Version (version number), with the functions:

  1. Param Set
  2. Live Param
  3. Variables
  4. Monitor
  5. Log
  6. Script

Within each Function the user may open several times the same tab with the Shift + Click key combination. The System Pro allows the user to manage multi-tabs simultaneously, i.e. the ability to open up to four functions on the same screen, thereby customizing and splitting the screen according to the user’s needs . To make use of the multi-tab mode drag the tab you want to appear over the work screen, do not release until the 4-Dial tool appears to select the desired position of the tab on the screen. Please find below a Multi-tab management example:

4.1.PARAM SET #

The Param Set function is used to access the complete parameter list of each program that has been created for a product. To create a new program click on the right button the Param Set function and select the item New Param Set. Enter the name of the new parameter set and, once the operation is complete, the program, its code and name are added within the Param Set folder. The user can create Param Set subfolders to better organize the program archive. To create a subfolder right-click the Param Set Item and select New Folder.

Folder and Subfolder Organization Example:

 

To access the program double-click on the left button or open it with Open by single-right click. The following functions are available with the right-click:

  • Rename the program
  • Clone the program
  • Export the program file with .tim extension
  • Eliminate the program

Upon opening the selected program the organized default parameter list appears with the following structure:

Grouping > Value > Parameters (ex. Combustion Recipe 2 > Extraction Fan with Encoder > V 05: Power 3)

The coloured column displays the value of each parameter. To the right of the value column you can read units of measure, and the upper and lower limits of the parameter. Double-click the parameter value to enable its modification. Then press the Enter key or click on the next parameter. The modified parameter is highlighted by an arrow showing the newly entered parameter.

 

The function buttons at the top of the Param Set tab allow the following operations:

Save the modified parameter values of the program.

Expand the parameter tree.

Close the parameter tree

Comparison of two different parameter lists of the same product. To use this feature, open a second parameter tree with the multi-tab (see Par.5) on the same screen as the reference parameter tree, and drag the key on top of the second parameter tree. Different value parameters will be highlighted with a green symbol and the number of detected differences is indicated in the bottom of the screen.

Program the Control-Board with the current program.

Download the current program to the USB Programmer device.

Search for a parameter by code, text string or word. The parameters that have been searched for and found will be highlighted in green, it will be possible to view these in sequential order by using the  arrows adjacent to the space dedicated to searching. The search system is not case sensitive.

Connect or Disconnect the tab from the System Pro main screen.

Close the tab.

4.2.LIVE PARAM #

The function Live Param allows the user to have the program interact directly with the control-board. In this modality it is possible to read and write parameters by changing the values in live-modality. To start this function click the right key of the mouse the Function Live Param, select the item New Live Param and insert the corresponding name. Upon opening Live Param the user can choose one of the following modes:

  1. Open previous session: the previous session is opened.
  2. Control-Board database reading: The user may read the program in the Control-Board connected to the PC. In this case, the user must wait for a minimum parameter reading time.
  3. Open database from Param Set: The parameter list of a specific program in the Database is opened.

 

The function keys at the top of the Live Param tab allow the functions described below:

Enter in modality Structure Construction. Customization of your Parameter List Folders.

Program the Control-Board with the current program.

Parameter List reading from the Control-Board.

Expand the parameter tree.

Close the parameter-tree.

Save the parameter list within the programs available in the Param Set function.

Search a parameter by code, text string or word. Those parameters searched for and found will be highlighted in green, and can be viewed in sequential order by using the arrows  adjacent to the space dedicated to searching. The search system is not case sensitive.

 

4.3.VARIABLES #

The Variables function allows the user to visualize and modify the value of all the system variables. To access the live view click on the Live button, the green led indicates that a proper connection has been established. The variable highlighted in red shown by the icon with letter A indicates a modifiable value. The variable highlighted in green identified by the other icon is only for reading purposes.

 

The value of a variable can be changed by writing in the Value column the corresponding number of the variation of the searched system.

For example with the Variable State it is possible to force the functioning state of the system by inserting the following corresponding numbers:

0

OFF

5

RUN MODE

1

CHECKUP

6

MODULATION

2

IGNITION

7

EXTINGUISHING

3

STABILIZATION

10

IGNITION RECOVERY

It is possible to force the amount of time of a system state by changing the value in the Timer column, for example by changing the timer value of the Periodic Cleaning. To obtain an updated list of available variables for your product please contact TiEmme elettronica. The Structure Construction modality key allows the user to customize his own variables list with a simple flag selection tool.

Furthermore with a right click of the variables tab that was previously created it is possible to perform the following functions:

  • Open the variables set
  • Rename the variables set
  • Clone the variables set
  • Export the variables set in a .xml file
  • Import the variables from a .xml file
  • Eliminate the variables set

4.4.MONITOR #

The Monitor function allows the user to have more than one monitor other than the default one provided by TiEmme elettronica. Click on the right button of the mouse on the Monitor function to create a new monitor or to import a previously created one. Monitor files can be either exported or imported and are .cfrm extension files.

Click on the right button of the mouse above a previously created monitor to:

  • Open the monitor
  • Rename the monitor
  • Copy the monitor
  • Export the monitor in a .cfrm file
  • Delete the monitor

Once the monitor has been opened the user may begin a session by clicking on the Monitor button, the led will turn green to confirm a successful connection. With the Developer Modality button (highlighted in red in the image below) the user may access the development page to customize the monitor.

With the button  it is possible to disengage the tab from the System Pro work screen. The  button is used to automatically resize the monitor window.

4.5.LOG #

The Log function allows the user to make a log containing all the system variable numbers/values. This feature allows the user to analyze in fine detail the trend of all the variables that come into play and to export the collected data so that it may be reworked to conduct analysis checks and tests. A new log session is started by right-clicking the Log function. At this point the user is asked to select a name for the log file and to select the sampling-time for the log session.

By clicking on the OK button the log moves on to the live session and starts to acquire data from the control system. To end the data acquisition click on the right button of the mouse on the log that has just been created and select Stop Current log. More than one log can be opened simultaneously by clicking shift+click on the just opened log tab.

4.6.SCRIPT #

The Script function allows the user to create a file to send a list of commands to the control-board; the following functions can be performed:

  • write_param(<PAR_NUM>, <PAR_VALUE>): writing of a parameter;
  • write_var(<VAR_NUM>, <VAR_VALUE>): writing of a variable;
  • read_param(<PAR_NUM>): reading of a parameter;
  • read_var(<VAR_NUM>): reading of a variable;
  • wait(<SECONDS>).

By right-clicking the Script Function create a New Script , at this point the user will be prompted to assign a name to the file. By double-clicking the left button of the mouse on the Script a window will open to create or modify a file, use the icon  to save and the icon  to execute the Script.

Right-click of the mouse on a previously created Script to:

  • Open the Script
  • Rename the Script
  • Copy the Script
  • Save the Script with the name
  • Delete the Script

5.GESTIONE DATABASE #

5.1.IMPORT PROGRAM/DATABASE #

To import a Product or a Database enter in File > Import Program/Database or from Database Products (see. Par. 4.1.1) click on Import.

With this tab the user may select what to import:

  • File with .tim extension
  • System Evolution 4 database with .mdb extension
  • System Pro database with .db extension

If a product contains more than one language it is necessary to import all the languages of that product. When a database is imported it is possible to select the products (by default all available products are selected). If the System Evolution 4 database is imported it is necessary to indicate the import language, from this moment on all such products will be identified with the associated language. When a program with .tim extension is imported the software automatically detects the language if in the file name the format “_XX_” is already present. The XX corresponds to the international language identifier, otherwise the user must select the import language.

5.1.1.IMPORTAZIONE DI UN DATABASE DA SYSTEM EVOLUTION #

Se viene importato il database di System Evolution 4 è necessario indicare la lingua di importazione, da questo momento in poi tali prodotti vengono identificati con la lingua associata.

Se viene importato un programma con estensione .tim il software rileva automaticamente la lingua se nel nome del file è presente il format “_XX_”, dove XX è l’identificativo internazionale della lingua, altrimenti è necessario selezionare la lingua di importazione.

Di seguito viene spiegata la procedura corretta di importazione di un Database da System Evolution.

  1. Richiedere a Tiemme elettronica i set parametri Default_IT/EN.tim per ogni prodotto di interesse. Per esempio: se si utilizza il prodotto SY250 AIR STD3, cod.441, richiedere set parametri di default del codice 441, disponibile in italiano o in inglese. Si riceverà quindi il set parametri Default_IT.tim o Default_EN.tim.
  2. Aprire System Pro e importare i set parametri Default inviati da Tiemme. Seguire il percorso: FileàImporta Programma/Database e scegliere il Default_IT.tim o Default_EN.tim inviati da Tiemme.
  3. Esportare il database da System Evolution andando in: Strumenti à Esporta Database à Esporta database Sistema
  4. Salvare il file System2000.mdb in una cartella del computer
  5. Aprire SystemPro e andare nuovamente in File à Importa Programma/Database e scegliere il database System2000.mdb precedentemente salvato nel computer. Stare attenti, al momento in cui si apre la finestra di ricerca, a selezionare nella finestra di scelta in basso a destra, la tipologia di file .mdb dall’elenco, in modo che il database (che ha appunto estensione .mdb) possa essere visibile e selezionabile.

A questo punto, andando ad aprire un prodotto, saranno presenti i set parametri precedentemente creati in System Evolution, la cartella Monitor conterrà il monitor di Default del prodotto e la cartella Variables sarà popolata; il tutto senza aver aggiornato la struttura del set parametri in modo da avere retro compatibilità.

5.2.EXPORT PROGRAM/DATABASE #

To export a Database enter in File > Export Database.

The following screen appears:

With this tab the user may select to export:

  • System Evolution 4 Database with .mdb extension
  • System Pro Database with .db extension

To export the program of a Product ( .tim extension) it is necessary to open the product (see Par.4.1.2) and export a program from Param Set (right-click of the mouse). If a product contains more than one language it is necessary to repeat the procedure for all the languages of the product. The name of the export file has the “SYEVOXXXXXXX_Nome Param Set_YY.tim” format, where XXXXXXX is the EVO code of the product and YY is the export language.

5.3.REPLACE DATABASE #

La procedura di Replace Database permette di sostituire l’intero database .dbz (costituito dai prodotti e log) con un altro precedentemente esistente ed esportato.

5.4.BACKUP DATABASE #

The software automatically generates a backup copy in the file C:\Programs(x86)\TiEmme elettronica\SystemPro\data\backups on a daily backup basis. At the very first system start-up a backup copy named SystemPro_AAAAMMGG.db is generated.

6.STRUMENTRI DI SYSTEM PRO #

6.1.TPX GENERATOR #

Il tool TpX Generator permette di creare i file del programma (file .tpr) e del firmware e programma insieme (file .tpp) per l’aggiornamento della scheda di controllo attraverso il programmatore palmare KeyPro. All’apertura del software compare la seguente schermata.

6.2.FIRMWARE DOWNLOAD #

In Strumenti → Firmware Download si apre la finestra di riprogrammazione firmware.

È necessario selezionare la porta di comunicazione (porta COM) usata. Si può cliccare la freccia verde per aggiornare automaticamente la lista delle porte COM.

6.2.1.DOWNLOAD FIRMWARE IN THE DEVICE #

Configure as follows:

  • Connect the USB Programmer to a USB port of the PC with cable CN2 (In case you need to install the device drivers, see Appendix B)
  • Make sure to use the proper COM port (see Appendix B)
  • Connect the USB Programmer to the RS232 Serial Port of the control-board with CN1 cable
  • Select the Device firmware download modality and follow the guided procedure
  • Select the file with .tfw extension that contains the firmware to download

At the end of the procedure:

  • Remove power supply from the Control-Board
  • Disconnect the USB Programmer from the PC and the Control-Board
  • Supply power to the Control-Board

6.2.2.SAVING THE FIRMWARE IN THE USB PROGRAMMER #

Configure as follows:

  • Connect the USB Programmer to a USB port pf the PC with CN2 cable (In case you need to install the device drivers, see Appendix B)
  • Make sure to use the proper COM port (see Appendix B)
  • Select the USB Programmer firmware download modality and follow the guided procedure
  • Select the file with .tfw extension that contains the firmware
  • At the end of the procedure disconnect the USB Programmer

To program the Control-Board with the USB Programmer see Appendix A.

 

6.2.3.USB PROGRAMMER FIRMWARE UPDATE #

Configure as follows:

  • Connect the USB Programmer to a USB port of the PC with CN2 cable (In case you need to install the device drivers, see Appendix B)
  • Make sure to use the proper COM port (see Appendix B)
  • Select the firmware download modality Update USB Programmer and follow the guided procedure
  • Select the file with .tfw extension that contains the firmware
  • At the end of the procedure disconnect the USB Programmer.

6.3.AREA DOCUMENTALE #

INTEGRARE

6.4.4WEB #

INTEGRARE

7.SYSTEM PRO SERVICE #

7.1.INTRODUZIONE ALLE CARATTERISTICHE DEL SYSTEM PRO SERVICE #

System Pro Service è un software Tiemme Elettronica sviluppato appositamente per coloro che si occupano del service dei prodotti. Questo software permette di gestire i programmi delle centraline Tiemme personalizzati dal costruttore dei sistemi di riscaldamento.

System Pro Service (in seguito SPS) si presenta con lo stesso layout del software System Pro.

L’utente ha a disposizione le stesse funzioni introdotte nei paragrafi precedenti e la stessa gestione dei programmi.

Prima di accedere al Software SPS è indispensabile essere in possesso di due file:

  1. Certificato di autorizzazione all’accesso al Software (.spscert)
  2. Programma di gestione della centralina in formato compatibile con SPS (.ctim)

7.2.GESTIONE CERTIFICATI SPS #

La creazione di un certificato di accesso a SPS avviene soltanto all’interno di System Pro. Cliccando il tasto di selezione rapida si accede alla finestra di creazione del certificato.

7.2.1.CERTIFICATE DISTRIBUTOR #

All’interno di questa sezione possono essere inseriti ID, Descrizione ed Indirizzo di riferimento dell’azienda distributrice dei certificati.

7.2.2.SPS CERTIFICATES #

All’interno di SPS Certificates si può creare un nuovo certificato. Cliccando su “Add Customer Certificate” è possibile creare un nuovo Cliente, inserendo:

  • Service Company ID: codice identificativo del cliente che viene riportato nel nome con il quale viene salvato il certificato;
  • Service Name: nome del cliente che viene salvato nella propria pagina di gestione;
  • Address: indirizzo della sede del cliente.

Attraverso la banda superiore è possibile ricercare il certificato o il cliente desiderato.

Una volta completata la redazione delle informazioni, cliccando su “Save Certificate” si può esportare il certificato SPS salvandolo nella directory scelta.

7.3.CREAZIONE DEL PROGRAMMA PER SPS #

System Pro Service può gestire soltanto programmi con estensione .ctim. Per creare questi programmi, si deve cliccare sull’icona  presente nella dashboard del Param Set (per indicazioni sulla posizione del tasto, vedi 4.1.

7.3.1.BARRA DEGLI STRUMENTI #

La barra degli strumenti viene così modificata:

Ingresso/Uscita modalità Costruzione struttura SPS. Permette la modifica della struttura dei parametri.

Programmare la scheda di controllo con il programma corrente. Funzione non abilitata nella modalità Creazione SPS.

Espandere interamente l’albero dei parametri.

Collassare interamente l’albero dei parametri.

Salvare il programma .ctim creato.

Ricercare un parametro per codice, stringa o parola. I parametri ricercati e trovati saranno evidenziati in verde, è possibile visualizzarli
in sequenza utilizzando le freccette adiacenti allo spazio dedicato alla scrittura di ricerca. Il sistema di ricerca non è case sensitive.
Apparirà anche l’icona di matching, che permette di mettere in evidenza l’elemento della ricerca.

Confrontare i valori presenti nel programma con un Live Param esistente.

Esportazione dei parametri in formato CSV

Esportazione o visualizzazione dei parametri in formato PDF

Esportare il programma SPS

Barra di selezione dell’SPS che si sta modificando

Pulsanti di creazione ed eliminazione di un programma SPS.

Filtra i parametri secondo che questi siano stati resi NASCOSTI, VISIBILI o MODIFICABILI.

7.3.2.CREAZIONE ED ELIMINAZIONE DI UNA CONFIGURAZIONE #

All’entrata in modalità SPS, il software crea un programma “Default” sul quale è possibile modificare la gestione di ogni singolo parametro. Per aggiungere un nuovo programma SPS, cliccare su , scegliere un nome per il nuovo programma. Il software suggerisce automaticamente i nomi “Config2”, “Config3” e così via.

È possibile spostarsi tra una configurazione SPS e l’altra attraverso il menu a tendina dove si possono scegliere le varie configurazioni create.

Per eliminare una configurazione, clicca su.

7.3.3.GESTIONE DEI PARAMETRI #

Per ogni parametro è possibile decidere come viene visualizzato su SPS. La scelta ricorre tra tre condizioni che il parametro può assumere:

  • Nascosto: Il parametro non è visibile nel nuovo programma .ctim che si sta creando
  • Visibile: Il parametro è visibile, quindi si può vedere il suo valore
  • Modificabile: il parametro è visibile, ed il suo valore modificabile

Per poter muoversi tra queste tre condizioni cliccare sulla barra colorata “SPS State” di ogni singolo parametro.

Il menu permette di selezionare la condizione desiderata per il parametro stesso.

Il colore del font dei parametri è variabile in base al criterio scelto:

  • Rosso: in caso di parametro modificabile
  • Nero: in caso di parametro visibile
  • Grigio: in caso di parametro nascosto

Per andare ad evidenziare soltanto i parametri che hanno una particolare condizione rispetto agli altri, si può usare il tasto . Attraverso l’apertura di un menu a tendina che permette di scegliere tra:

Disabilitando una condizione, i parametri che sono stati configurati con la stessa non vengono mostrati nell’elenco, così da facilitare la ricerca degli altri.

7.3.4.ESPORTAZIONE DELLA CONFIGURAZIONE SPS CREATA #

Al termine della modifica della configurazione SPS, cliccando su  si esporta la configurazione in formato .ctim. il software chiede quindi di indicare a quale Certificato associare il programma, tra i certificati precedentemente creati ed associati ai vari service.

Il programma viene quindi salvato su PC, con estensione .ctim e con dicitura 

ID_descrizione programma e codice_lingua_nome configurazione.ctim” .

7.4.INIZIALIZZAZIONE SYSTEM PRO SERVICE #

L’installazione del software su computer avviene tramite un file di setup.exe fornito da Tiemme. Seguire la procedura guidata per completare l’installazione. La struttura grafica e funzionale del software è identica a quella già descritta per System Pro: stessa metodologia di connessione al PC ed ai dispositivi di collegamento USB Programmer e KeyPro, stessi tasti di selezione rapida, stessa gestione in cartelle e sotto cartelle dei prodotti.

7.4.1.CERTIFICATO SPS #

Per avere la possibilità di utilizzare il SPS è necessario essere in possesso di un certificato di accesso. Questo certificato viene redatto da parte del fornitore e il file ha estensione: .spscert ().

All’apertura del software, viene richiesto di scegliere il certificato attraverso il quale si abilita l’accesso. Non è possibile utilizzare il software senza alcun certificato importato. Nella finestra vengono visualizzati i certificati già importati. Basta quindi selezionare il certificato desiderato e cliccare su “Usa il Certificato selezionato”. Qualora non siano presenti certificati, si possono importante cliccando su “Aggiungi Certificato” e selezionando il certificato.spscert presente sul proprio computer.

7.4.2.IMPORTAZIONE ED ESPORTAZIONE PRODOTTI #

Come già visto per System Pro, attraverso la finestra “Database Prodotti” è possibile visualizzare i prodotti presenti all’interno del software. In questo caso però, SPS consente l’importazione di programmi solo con estensione .ctim.

L’esportazione dei programmi da SPS avviene sempre cliccando con il tasto destro il Param Set desiderato e selezionando “Esporta”. In questo caso il programma ha estensione .tim .

8.APPENDIX A #

8.1.USB PROGRAMMER #

USB Programmer is a device capable of:

  • Memorizing up to 3 programs containing the parameters of the Control-Board.
  • Updating the Control-board with one of the three memorized programs
  • Saving a firmware to manage the Control-Board
  • Updating the Control-Board with the saved firmware

 

8.1.1.BUTTONS #

Button Sing Function
P1 START Start programming
P2 SEL Selection of program parameters

8.1.2.LED #

Button Sing      Function
L1 POWER      Led ON: Programmer powered
L2 COM/DONE      Led ON: programming completed / Led flashing: ongoing programming
L3 ERROR      Led ON: error signal
L4 FW/READY      Led ON: Programmer ready for the Control-board firmware update
L5 READY      Led ON: Programmer ready for the Control-board parameter update
L6 SEL1      Led ON: Program 1 selection
L7 SEL2      Led ON: Program 2 selection
L8 SEL3      Led ON: Program 3 selection

9.APPENDIX B #

9.1.USB PROGRAMMER DRIVERS INSTALLATION #

Installation the drivers required for interfacing with the USB Programmer device is performed during the installation of the System PRO Software. Should the automatic installation fail it is possible to proceed manually, by launching the setup file USBdriverssetup.exe that can be found in the installation cd in the directory X:Drivers (X identifies the driver where the Cd-Rom is present). During the installation procedure the operating system automatically assigns a COM port number. If communication problems occur with the USB Programmer device it is necessary to verify in the control panel to manage devices for Vista, Win7, Win8 and Win10, and in Control panel HW system peripheral management for WinXP, that the assigned port number is between 1 and 16. If this condition is not verified, the user must manually reassign a port number within the specified range. Drivers are digitally signed by TiEmme elettronica to ensure their origin. In Windows Vista, 7, 8 and 10 operating systems during the drivers installation the following windows will appear. If the user flags “Always consider software reliable coming from” these windows will not appear again on subsequent installations.

10.APPENDIX C #

10.1.LIST OF TIEMME ACRONYMS #

File extension Description
.tpp TPP (TiEmme Product Package)
Contains both firmware and resources. Encrypted File with 64 bit key. Any additional resources such as the graphics for the Easy Touch keyboard or a parameter list can also be integrated into the file.
.tpr TPR (TiEmme Product Parameter)
Only contains resources such as the parameter set. Of identical structure to a TPP file but without containing the FW. Encrypted file with 64 bit key.
.tfw TFW (TiEmme FirmWare)
File Firmware of TiEmme elettronica products.
.tim TIM (TiEmme file)
File which includes the parameter set, variables and monitor (only in the System Pro version).
.mdb Database of System Evolution 4
Database which includes products and programs.
.db Database of System Pro
Database that includes products and programs it is different from a .mdb file by having the possibility of language diversification.